Input Data (DC) |
Normal DC Power |
6000W |
Max. DC voltage |
500Vdc |
Voltage Range |
100~450Vdc |
Max. input current |
0 ~ 10A x 3ch (R / 0.01A) |
Current rise time |
250ms |
Output Data (AC) |
Normal AC Output |
5700W |
Max. AC current |
25A |
AC Voltage |
220Vac / 200 – 250 Vrms |
AC Frequency |
50Hz / 60Hz |
Power factor |
0.99 |
Phase |
Single-phase |
Dimension |
|
(W x H x D) in mm |
585 x (425 550) x 180 |
Efficiency |
|
Max. Efficiency |
96% |
Cooling Capacity |
Fan |
Others |
|
Compliance |
EN 61010 / VDE 0126-1-1\
EN 61000-6-2 / EN 61000-6-3\
EN 61000-3-11 |
THD |
<3% |
Communication |
RS-485 |
Current Setting Scale |
0.10 10.00A (R/0.01A) |
Current Reading |
R / 0.01A |
Programmable to set the input current value |
Monitor System (Max. 255 port) / remote monitoring |
RS-232 / RS-485 communication Port |
Waveform |
True sine wave / on Grid Type |
Loading Current Ripple |
-±1% full scale ±0.1A (Vp-p) |
1 Phase transformer-less type 2Kw module (flexible assembly power watt. & phase) |